Posts

microcontroller - Why is the Voltage only 1.4 for reset input when in high impedance? - Electrical Engineering Stack Exchange

Image
i attempted make myself 2-in-1 programmer can program both at89cx051 , at89s52 on same board without having plugging/unplugging of port. the main issue strobe pin aka reset (rst in circuit). (pin 1 of db25 connector). tested pc , got no results. what seems work if connected rst vcc via 1k resistor. works because though output @ 3.8v instead of 5 (which vcc at), puts at89s52 in reset mode expected, i'm not getting 12v @ pin 1 of small at89cx051 socket. if don't make manual connection, 1.4v measured @ rst, after added 10k resistor between vcc , rst. without rst being forced ground, should 5v i'm not. i have tested transistors manually leg leg using diode setting on multimeter , turned out fine. resistors going base of transistors 2.2k , used 1k resistors in place of diodes. other resistors 10k. resistor going buffer (74hc125) 0 ohm. all capacitors 0.1uf. why getting such awkward voltages reset pin? using weak of resistors or something? update so ended ma...

Is there any standard size in Custom PCB Manufacturing? - Electrical Engineering Stack Exchange

Image
i have no experience of dealing pcb manufacturers except time once used pcbway's service. know if there standard pcb board sizes 1 needs create when getting custom pcb made? my basic idea not incur cost loss of material pcb manufacturer faces. example, let's use board of 10*10 inch manufacture , submit custom board request dimension of 7*7 inch, increase cost of pcb? sometimes pcb makers have per-panel price. tell size using..or more importantly, area have work with-- usable area (not panel size) @ least 10" x 16", maybe 10.5" x 16.5" or bit more. small panel. large production believe larger panels more typical. typically phenolic single sided boards use larger panel sizes. this reference lists typical standard pcb panel sizes follows: panel borders (maybe 0.5" on each side) take away area. it not particularly important unless pcbs (or self-panelized pcbs) getting size few panel- materials not biggest part of pcb cost in prototype...

Trouble with selecting a single wire segment of a net in Altium - Electrical Engineering Stack Exchange

Image
below want select , edit bottom wire of 3 parallel wires: but when click on bottom wire program selects middle wire because share same net. is possible single out desired wire segment without selecting entire net in altium? yes you need use "break wire" feature first - split wire up. think it's in "edit" menu.

analysis of two transistors ib,ic,ie? - Electrical Engineering Stack Exchange

Image
is ib current correct went kvl through first transistor your forgetting re. you need use effective resistances r4 , r6, value \$r4_e = r4 * (1+\beta) = 40,000 * 101 = 4,040,000\omega\$ \$r6_e = r6 * (1+\beta) = 1,000 * 101 = 101,000\omega\$ using base circuit looks this. simulate circuit – schematic created using circuitlab you solve using various methods, shortcut realise that, ideal vbe, voltage @ top of both emitter resistors identical. such can treat both legs being in parallel. circuit can further simplified to.. simulate circuit now should able calculate current through circuit as.. \$i_{rb} = (2.6 - 0.6)/(2,260 + 98,540) = 19.84ua\$ that makes base voltages both.. \$v_b = 2.6 - 19.84ua * 2.26k\omega = 2.555v\$ so \$ib1 = (2.555-0.6)/4.04m\omega = 0.484ua\$.. , \$ib2 = (2.555-0.6)/101k\omega = 19.356ua\$ however: these numbers make sense if transistor not saturated. question states \$i_e \approx \beta * i_b\$ indicates ...

UPS battery advice - Electrical Engineering Stack Exchange

i have apc ups 9 ah battery. would ok replace 18 ah battery? i realize modifications needed since won't fit in case. in theory shouldn't matter how bigger ah rating of battery long regulate current , voltage same. takes long transfer coulombs of charge. bigger battery of same chemistry have larger capacitance , may have lower esr.

Nyquist-Shannon sampling theorem on non infinite signals - Electrical Engineering Stack Exchange

Image
can sample , recover signals non infinite "length" using nyquist shannon theorem? example if have signal $$ x(t)= u(t+5)-u(t-5) $$ , know sampling period t less 10s (t<10). can recover using nyquist theorem? if not , recover it? edit: have taken fourier transform of signal , : $$x(ω)=2i(\frac{1}{iω}+πδ(ω))sin(5ω)$$ can lead finding period $$\frac{2π}{5} $$ , see if f>= 5/π can recovered. may not possible because used theorem although on finite signal no need think "finite length". though continuous time signals defined infinite time interval, in practice analyse in finite interval only. x(t) defined in interval [-5 5]. the frequency domain representation of such signal infinite bandwidth sinc function. hence not possible define particular sample rate per nyquist theorem, reconstruct without losing information. can sample definite sample rate, implicitly band limits signal. sampled signal after reconstruction through dac , lpf, not pe...

how to determine the current capability of a transformer - Electrical Engineering Stack Exchange

Image
hello have transformer ebay north court 50 amplifier. there not information online. has 400 0 400 volt ht think ran pair of kt66 valves gz34 rectifier dimensions l x b x h 4" 3" 4" if can me out on 1 great the main determiner of transformer power rating material , cross-sectional area of core. sets power level @ core saturate, , manufacturers don't want use more steel absolutely have to. as rough estimate, since these transformers use same kind of steel laminations , same relative geometry, sufficient make judgement based on volume/mass of core. since core majority of total mass of transformer (the windings tiny fraction), weighing enough, why marko made comment.